Presented at: 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Milano, Italy, August 25-29, 2015- Publication date: 2015
Error-related EEG potentials (ErrP) can be used for brain-machine interfacing (BMI). Decoding of these signals, indicating subject’s perception of erroneous system decisions or actions can be used to correct these actions or to improve the overall interfacing system. Multiple studies have shown the feasibility of decoding these potentials in single-trial using different types of experimental protocols and feedback modalities. However, previously reported approaches are limited by the use of long inter-stimulus intervals (ISI>2s). In this work we assess if it is possible to overcome this limitation. Our results show that it is possible to decode error-related potentials elicited by stimuli presented with ISIs lower than 1s without decrease in performance. Furthermore, the increase in the presentation rate did not increase the subject workload. This suggests that the presentation rate for ErrP-based BMI protocols using serial monitoring paradigms can be substantially increased with respect to previous works.
Reference
- Detailed record: https://infoscience.epfl.ch/record/209006?ln=en
- EPFL-CONF-209006
- doi:10.1109/EMBC.2015.7318560